Ergonomic Research

We tested The Body Shelf with surface electromyography and published everything that came back — including the results that were smaller than we hoped.

Why we publish the whole dataset

It is easy to find a flattering number in a study and put it on a banner. We used to do that. The old headline — "50% less strain" — was a male-subject average, described with a word the study never measured. We have retired it.

What follows is the complete picture: what was measured, how, what every task produced, and what this evaluation cannot tell you.

What surface EMG measures — and what it does not

Surface electromyography places electrodes on the skin over a muscle and records the electrical signal it produces when it contracts. Lower signal means that muscle did less electrical work during that movement.

It is not a measurement of load in pounds on the spine, strain in any engineering sense, pain, perceived effort, total physical work, or injury risk. Those are different quantities requiring different studies.

Methodology

Date February 2023
Design Combined objective (sEMG) and subjective (questionnaire) ergonomic evaluation
Subjects 11 total — 8 male, 3 female. Mean age 43 (range 17–58)
Loads Sand-filled boxes, 12.5" × 12.5" × 16", at 25 lb and 50 lb. Male subjects handled both; female subjects handled 25 lb only
Tasks Flat carry · lift-and-twist · lift-and-pivot · stairs without handrail · stairs with handrail
Comparison Each task performed with The Body Shelf and unaided
Measurement sites Back and lower-back musculature, left and right recorded separately
Statistical testing None reported
Peer review None. Authors, laboratory and institution are not named in the document

Results — reduction in measured back-muscle activity

Male subjects

Task 25 lb 50 lb
Flat carry 51% 36%
Lift and twist 56% 35%
Lift and pivot 60% 53%
Stairs, no handrail 43% 22%
Stairs, with handrail 56% 2.8%

Female subjects, 25 lb

Task Result
Flat carry 12.5% at back sites; 19% aggregated across measured sites
Lift and twist 21% right lower back; left side showed no reduction
Stairs, no handrail 36% left back
Stairs, with handrail 6.5% left back

The evaluation summarised male results as approximately 50% at 25 lb and 39% at 50 lb, without publishing the calculation behind those figures. We therefore quote the task-level range — 36–60% for male subjects across 25–50 lb loads — rather than a single number.

Subjective ratings (1–5 scale)

Measure With harness Unaided
Overall comfort 4.5 3.3
Low back comfort 4.75 2.96
Perceived productivity 4.6 3.1

These are self-reported in an unblinded test and are subject to expectation effects. They are still meaningful — comfort determines whether equipment gets worn on hour seven of a shift — but they are opinion, not measurement.

Three things the data actually tells you

Reductions were larger at 25 lb than at 50 lb across every male task. At heavier loads, more of the work falls outside what a passive shelf can absorb.

One-handed carries lose most of the benefit. Stairs with a handrail at 50 lb produced 2.8% — the smallest figure in the dataset. If one hand is on the rail, expect substantially less support.

Results differed by sex. Female subjects saw smaller and less consistent reductions. The evaluation hypothesised that handrail height relative to subject stature may have caused asymmetric loading. That is a hypothesis, not a finding.

Limitations

  • Small sample — 11 subjects, only 3 of them female. Directional, not definitive.
  • No statistical significance testing. Some portion of these differences may reflect normal trial-to-trial variation.
  • Not peer-reviewed; authors, lab and institution unnamed. We are working to commission an independent, properly attributed follow-up.
  • Measured muscle activity, not injury. No injury rates were tracked. Nothing here demonstrates injury prevention and we do not claim it.
  • Female results were smaller and inconsistent; male-only summary figures would misrepresent the dataset.
  • Only two load points tested. The suggested 20–50 lb "optimal range" is an inference, not a measured curve.
  • Fit and familiarity materially affected results.

Download the evaluation

Download the February 2023 ergonomic evaluation (PDF, 291 KB)

Related reading

The Body Shelf is a passive carrying support tested to 50 lb. It does not replace safe lifting technique or employer-required controls.